Hammond Eclipse Series Hinge Door with Quarter Turn and Window
Hammond MFG- Description
- Specifications
- NEMA Ratings
-
Designed to enclose electrical and/or electronic equipment in wall mount applications where viewing of component operation is necessary while maintaining protection ratings. Impressive styling features like hidden hinges, attractive latching systems make the Eclipse a suitable addition to any high-tech equipment installation. A wide range of sizes and practical accessories make this product line a complete package.
Standards
- UL 508A Type 3R, 4 and 12
- CSA Type 3R, 4 and 12
- NEMA 3R, 4 and 12
- IEC 60529, IP66
-
Specifications
Please click a part number below to view the product specifications.
Product dimensions
Part Number
16x12x6 EN4SD16126WGY 20x16x6 EN4SD20166WGY 20x20x6 EN4SD20206WGY 24x20x6 EN4SD24206WGY 24x24x6 EN4SD24246WGY 16x12x8 EN4SD16128WGY 20x16x8 EN4SD20168WGY 20x20x8 EN4SD20208WGY 24x20x8 EN4SD24208WGY 24x24x8 EN4SD24248WGY 30x24x8 EN4SD30248WGY 20x20x12 EN4SD202012WGY 24x20x12 EN4SD242012WGY 24x24x12 EN4SD242412WGY 30x24x12 EN4SD302412WGY 24x24x16 EN4SD242416WGY 24x24x20 EN4SD242420WGY 30x24x20 EN4SD302420WGY -
Type 3R
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.
Type 4
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose-directed water); and that will be undamaged by the external formation of ice on the enclosure.Type 12
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).