Hammond Eclipse Disconnect Series Hinge Door with Handle (Flange w/ multi-vendor cutout)
Hammond MFG- Description
- Specifications
- NEMA Ratings
-
Designed to house safety disconnect equipment. Cover and enclosure are finished in re-coatable smooth ANSI 61 gray powder coating.
Standards
- UL 508A Type 3R, 4
- CSA Type 3R, 4
- NEMA Type 3R, 4, 12 and 13
- IEC 60529, IP66
- Appropriate components are required to maintain these standards.
-
Specifications
Please click a part number below to view the product specifications.
Product Dimensions
Part Number
20x22x8 in. EN4DSC20228GY 24x22x8 in. EN4DSC24228GY 24x26x8 in. EN4DSC24268GY 30x26x8 in. EN4DSC30268GY 36x26x8 in. EN4DSC36268GY 36x32x8 in. EN4DSC36328GY 42x32x12 in. EN4DSC423212GY 42x38x12 in. EN4DSC423812GY 48x38x12 in. EN4DSC483812GY 60x38x12 in. EN4DSC603812GY -
Type 3R
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.
Type 4
Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose-directed water); and that will be undamaged by the external formation of ice on the enclosure.Type 12
Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).
Type 13
Enclosures constructed for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing); and to provide a degree of protection against the spraying, splashing, and seepage of oil and non-corrosive coolants.